Modulation exposure shutters
NM Laser Products Inc
NM Laser offers a broad-based line of laser shutters with features and performance to meet the requirements of most laser applications. The patented laser shutters provided by NM Laser offers features not found in other types of mechanical shutters.

Modulation, Exposure and Pulse Gating Shutters

This family of shutters offers the fastest switching speeds and high sustained repetition rates. Modulation can be as high as 500 Hz, with exposures as short as 800 microseconds at FWHM. Single pulse extraction can be made from 2 KHz or lower pulse trains.

The fastest speeds are for the smaller aperture diameters, starting at 2.3 mm. Usually, the shutter package size and optical power rating escalates with increasing aperture size. Switching speeds slow with larger apertures, in a non-linear fashion.

The majority of packages are designed for common applications with commercially available lasers and high irradiance lamp sources.

Models are arranged in formats that indicate how the beam is intercepted by the moving flexure optic; the LS Models use near grazing incidence reflection principles and the LST Models use 45 degree incidence.

In general, the LS models move less mass, providing faster switching speeds. They also provide higher damage threshold since the beam is spread over a large elliptical area of the flexure optic.

Angles of incidence range from about 82 to 75 degrees, increasing the area of incidence and reducing the fluence by factors of 4-6. If the laser source is polarized, the damage threshold and optical power handling is further increased by aligned the polarization vector to the label on the product input aperture. This takes advantage of higher reflectivity of S polarization for near grazing incidence.

The absorber can handle a great deal of power, and usually the optical power rating is limited by the flexure optic.

The standard coating is a broadband aluminum coating. Gold is available for exclusive use in the IR by adding suffix −IR to the model number. At CO2 wavelengths, absorbers change as well, and the −C2 suffix is attached to the model number. Some models also have a suffix −P for high energy, low rep rates, typically YAG systems.

Some of the LST models, such as the LSTXY, are designed with dielectric optics and diffusers to handle high energy Q-Switched sources. Damage threshold ratings require dielectric optics. These models also have suffix designations for various dielectric mirror wavelengths.

Most models in this high speed family do not have position sensor options. Cable lengths on the shutters are nominally 8 feet. Extended cables can be ordered, with some limits due to voltage drop with distance.

These shutter models require more electrical power to provide fast switching speeds, and therefore dissipate more heat. Proper thermal mounting is mandatory to achieve stated performance and to avoid damage. See Thermal Mounting in the application notes section.

The fastest models require the CX2250 model controller. Larger aperture models can benefit from the dampened movement control provided by the CX4C controller. For some smaller aperture models, our CX2450B controller can provide lower speed operation, but check with factory sales engineers for a compatibility check.
nm1.pdf nm2.pdf nm3.pdf
Mechanical Shutter Systems
Vincent Associates
Vincent Associates provides mechanical shutters with a number of apertures and shutter types available to meet most applications.
Series
Aperture
Time to Open
BDS25
25 mm
13.0 msec
25 mm
9.0 msec
35 mm
13.0 msec
45 mm
14.0 msec
65 mm
29.0 msec
90 mm
70.0 msec
2 mm
300 µsec
3 mm
500 µsec
6 mm
700 µsec
QCS45
45 mm
14.0 msec
1 mm
180 µsec
14 mm
1.5 msec
25 mm
3.0 msec
35 mm
13.0 msec
XRS14
14 mm
20.0 msec
XRS25
25 mm
10.0 msec
6 mm
3.2 msec
Mechanical Shutter Systems
Mechanical Shutter Systems
Shutter Mounts
Vincent Associates

Vincent Associates has designed mounting systems for microscope and video that can be interfaced with popular microscopes.

MICROSCOPE MOUNTING SYSTEMS :
Mounting options available for Zeiss, Nikon, Olympus, and Leica type microscopes.

VIDEO MOUNTING SYSTEMS :
Can be interfaced with popular video systems for many types of video systems including "F-C", "C", and "T" video mounts.

UNIVERSAL MOUNTING SYSTEMS :
These universal mounting rings to allow our line of shutter devices to be easily integrated into user applications. These rings can be utilized from our 1mm aperture to the 90mm size.
uniblitz_Shutter_Microscope_Mounting.pdf Uniblitz_shutter_Video_Mounting.pdf uniblitz_Shutter_Universal_Mounting.pdf
Shutter Drivers
Vincent Associates
The new VCM-D1 controller has all of the features of the VMM-D1 and more.

VCM-D1 NOW CARRIES CE AND UL/CSA CERTIFICATION

With its new housing design, dual RJ45 RS-232 addressable serial interface, and new ODU push-lock shutter connector, (among other enhancements) provide a shutter driver unit even more versatile for the most demanding shutter applications.



Note :
    The VMM series of controllers will no longer be available in the European Union.
Uniblitz_Shutter_Driver_vcm-d1.pdf
OEM Board Level Shutter Drivers
Vincent Associates
For OEM applications, printed circuit board level drivers are available from Vincent Associates. These OEM driver systems have been used in many different applications and are designed to be powered from user supplied AC or DC voltages.
  • CCS-3 Open Frame Shutter Driver
  • Smallest UNIBLITZ shutter driver Open frame printed circuit card suitable for OEM applications
  • Power input: +12 VDC at 1 A
  • CCS-5 Open Frame Shutter Driver Open frame printed circuit card suitable for OEM applications
  • Power input: +24 VDC at 1.5 A
  • Direct or opto-isolated input control D880 Open Frame Shutter Driver Open frame printed circuit card suitable for OEM applications
  • Power input: +24 VDC at 1.5 A
  • Pluggable 12 position I/O connector 122-BP Open Frame Shutter Driver Open frame printed circuit card mounted to an aluminium chassis
  • Power input: 115/230 VAC 50/60 Hz
  • Pluggable 9 position I/O connector and 3 position AC connector
oem_shutter_drivers.pdf
SR540 - Optical Chopper
Stanford Research Systems - SRS
The SR540 chopper will handle all your optical chopping requirements - from simple measurements to dual-beam and intermodulation experiments.
  • 4 Hz to 3.7 kHz chopping frequencies
  • Low phase jitter
  • Single and dual beam experiments
  • Sum & difference reference outputs
  • Bolt clamp or rod mounting
SR540 - Optical Chopper
SR540 - Optical Chopper
  PHOTONICS    

  e-mail Netherlands
  Phone: +31 (0)172-44 60 69 or
  Phone: +31 (0)172-44 60 63
  e-mail Belgium
  Phone: +32 (0)2 712 54 46
 QuickSearch: 
    http://photonics.bfioptilas.nl/
    >Laser Safety & Accessories/Laser Modulation